01

Who this comparison is for

Most GFRP questions start with “is it cheaper than TMT?” The honest answer depends on the element, so this page is written for the people who will check the numbers.

Structural consultants

Engineers who need tensile strength, stiffness and bond stated separately before they redesign a member.

Procurement teams

Buyers comparing a per-kg steel rate with a per-metre GFRP rate and needing the lines that sit between them.

Project heads

Decision-makers weighing first cost against corrosion, maintenance and programme.

Contractors

Site teams who will carry, cut, tie and place the bar, and who carry the risk of scrap and theft.

02

The bar, property by property

Steel values are for Fe 500 grade, as 7 STAR’s literature presents them. The GFRP strength and modulus figures are the averages from the tensile test reports printed in the same literature (tests carried out for Armastek, 7 STAR’s technology partner).

The literature’s summary table gives 65 GPa for GFRP modulus. The printed test reports average 45–53 GPa by diameter, so the lower measured range is shown here. Use the supplier’s certified values for design.
Property TMT steel (Fe 500) GFRP rebar What it means
Tensile strength 500 MPa minimum About 1,050–1,240 MPa (test averages, 6–20 mm) More tensile capacity per square millimetre.
Modulus of elasticity About 200 GPa About 45–53 GPa (test averages) Roughly a quarter as stiff. Deflection and crack width often govern the design.
Elongation 12% minimum, with a yield plateau About 2–3% at failure, no yield Linear-elastic to rupture. No ductile warning, so safety factors differ.
Weight, 8 mm bar 0.395 kg/m 0.079 kg/m About one fifth of the weight at the same diameter.
Density 7.8 t/m³ 1.9 t/m³ Freight and handling change most.
Supply length 12 m bars Coils up to 100 m in small diameters; 12 m bars above 12 mm Fewer laps on long runs.
Corrosion Rusts if cover or exposure fail Does not rust The main reason to specify GFRP in wet, saline and chemical exposure.
Electrical and magnetic Conductive and magnetic Non-conductive and non-magnetic Useful near induction loops, sensitive equipment and electrical rooms.
Transverse shear 120 MPa 170 MPa Literature figure. Shear design still follows the GFRP design guide.
Bond strength 14 MPa 12.5 MPa Slightly lower. Development and lap lengths are calculated for GFRP.
Compression 500 MPa 450 MPa Design guides such as ACI 440.1R do not rely on GFRP bars in compression.
Concrete cover 35–45 mm 20 mm (literature figure) Cover follows the project code and fire rating, not the brochure.
03

What changes in the design

A GFRP schedule is a new design, not a find-and-replace on bar marks. These are the points a consultant will check first.

Strength is not the limit, stiffness is

With twice the tensile strength and a quarter of the stiffness, many slabs are sized for deflection and crack width, not strength. Bar area may fall, stay the same or rise.

Design guide changes

GFRP members are designed to FRP guides such as ACI 440.1R. Road components follow the references IRC:137-2022 sets out. A steel code is not applied to a GFRP bar.

Bends are made in the factory

GFRP cannot be bent on site. Stirrups and shaped bars are ordered against a drawing, so the bending schedule has to be ready earlier.

Laps and development lengths

Bond differs from steel, so lap and anchorage lengths are recalculated. Long coils can remove many laps on slabs, drains and pavements.

Fire and temperature

GFRP softens at high temperature. 7 STAR’s FAQ notes concrete cover protects the bar and fire-tested slabs stay structurally safe. Fire-rated members need the consultant’s check.

Mixed reinforcement

Many projects use GFRP in slabs, pavements and drains while columns and primary frames stay in steel. 7 STAR’s FAQ describes exactly that split for seismic zones.

04

How to compare the cost properly

Per kilogram, GFRP looks more expensive. Per metre and per finished element, the picture changes. These are the lines a fair BOQ comparison includes. Leave any of them out and the answer is wrong in one direction or the other.

Ask 7 STAR for the comparison on one real element, such as a slab, a drain section or a boundary wall panel, with every assumption written down.
Cost line What changes with GFRP What to check
Bar rate Higher per kg, far lower weight per metre Compare rate per metre and per element, never per kg alone.
Bar quantity Set by the GFRP redesign Use the consultant’s GFRP schedule, not a converted steel schedule.
Laps and overlap Long coils remove many laps Count the laps actually saved on the drawing.
Freight and lifting About one fifth of the weight Truck loads, crane time and manual handling on site.
Labour and placing Lighter bars and ready mesh place faster Crew size and days on your programme, not a brochure rate.
Scrap and reconciliation Cut-to-length supply; offcuts have no scrap resale market Your current steel wastage and reconciliation losses.
Corrosion protection No coatings or corrosion-inhibiting admixtures for the bar What the steel design specifies for exposure today.
Maintenance and life No rust-driven repairs Repair history of similar steel elements on your sites.
Price movement Steel rates move with raw material and market prices Agree a rate validity period for whichever material you buy.
Why there is no headline percentage here

Savings depend on the element, the exposure, the steel price on the day and how many of the lines above apply. 7 STAR prepares project-wise BOQ comparisons on request. That is the number worth using.

05

Where TMT should stay

An honest comparison includes the cases where steel is still the right bar.

Keep steel for these

  • Columns and members that work mainly in compression.
  • Primary beams and columns in seismic frames, where steel’s ductility is relied on. 7 STAR’s FAQ uses GFRP for slabs and secondary elements in seismic zones.
  • Members that must be bent on site.
  • Road components outside the IRC:137-2022 permitted list.
  • Fire-rated members, unless the consultant has checked GFRP for that rating.

GFRP suits

Slabs on grade, industrial and warehouse floors, pavements, drains, boundary walls, retaining walls, water tanks, STPs and precast items, especially in wet, saline or chemical exposure.

06

GFRP and TMT questions

Is GFRP rebar stronger than TMT steel?

In tension, yes. The tensile test averages printed in 7 STAR’s literature are about 1,050 to 1,240 MPa, against a 500 MPa minimum for Fe 500 steel. GFRP is also about a quarter as stiff and does not yield, so a stronger bar does not automatically mean a smaller one.

Is GFRP cheaper than TMT?

Per kilogram, no. Per metre and per finished element, it often is, once weight, laps, freight, labour, scrap and corrosion protection are counted. The answer is project-specific, so ask for a BOQ comparison on a real element.

Can I replace a 12 mm TMT bar with a 12 mm GFRP bar?

Not by substitution. The GFRP schedule has to be designed for its lower stiffness and different bond. Diameter and spacing may change in either direction.

Can GFRP be used in columns?

No. Columns and heavy compression members stay in steel. GFRP is used where reinforcement works in tension, such as slabs, pavements, walls and drains.

How long does GFRP last?

7 STAR’s literature gives a service life of 80 to 100 years or more, because the bar does not rust. Actual life also depends on concrete quality, cover and loading.

Can GFRP and TMT be used together?

Yes. A common pattern is GFRP in slabs, floors and drains, with steel kept in columns and primary frames. 7 STAR’s FAQ says the two can be tied together with normal binding wire on building work. Road works follow IRC:137-2022 tying rules.

07

Ask for a like-for-like BOQ

Send one real element, such as a slab, a drain section or a wall panel. The comparison lists every assumption. You can also call +91-7669275932 or write to contact@7stargfrp.com.

Application pages: Flooring · Roads & Drains · Standards · Precast & Bent. Or read the 7 STAR GFRP blog.